Everything about Gas Chromatography-mass Spectrometry totally explained
Gas chromatography-mass spectrometry (
GC/MS) is a method that combines the features of
gas-liquid chromatography and
mass spectrometry to identify different substances within a test sample. Applications of GC/MS include
drug detection,
fire investigation, environmental analysis,
explosives investigation, and identification of unknown samples. GC/MS can also be used in airport security to detect substances in luggage or on human beings. Additionally, it can identify
trace elements in materials that were previously thought to have disintegrated beyond identification.
The GC-MS has been widely heralded as a "
gold standard" for
forensic substance identification because it's used to perform a
specific test. A specific test positively identifies the actual presence of a particular substance in a given sample. A
non-specific test, however, merely indicates that a substance falls into a category of substances. Although a non-specific test could statistically suggest the identity of the substance, this could lead to
false positive identification.
History
The use of a mass spectrometer as the detector in gas chromatography was developed during the 1950s by Roland Gohlke and Fred McLafferty. These sensitive devices were bulky, fragile, and originally limited to laboratory settings. The development of affordable and
miniaturized computers has helped in the simplification of the use of this instrument, as well as allowed great improvements in the amount of time it takes to analyse a sample. In 1996 the top-of-the-line high-speed GC-MS units completed analysis of fire accelerants in less than 90 seconds, whereas first-generation GC/MS would have required at least 16 minutes. This has led to their widespread adoption in a number of fields.
Instrumentation
The GC-MS is composed of two major building blocks: the
gas chromatograph and the
mass spectrometer. The gas chromatograph utilizes a capillary column which depends on the column's dimensions (length, diameter, film thickness) as well as the phase properties (for example (5% (phenyl)polysiloxane. The difference in the chemical properties between different
molecules in a
mixture will separate the molecules as the sample travels the length of the column. The molecules take different amounts of time (called the retention time) to come out of (elute from) the gas chromatograph, and this allows the mass spectrometer downstream to capture, ionize, accelerate, deflect, and detect the ionized molecules separately. The mass spectrometer does this by breaking each molecule into
ionized fragments and detecting these fragments using their mass to charge ratio.
These two components, used together, allow a much finer degree of substance identification than either unit used separately. It isn't possible to make an accurate identification of a particular molecule by gas chromatography or mass spectrometry alone. The mass spectrometry process normally requires a very pure sample while gas chromatography using a traditional detector (for example Flame Ionization Detector) detects multiple molecules that happen to take the same amount of time to travel through the column (
for example have the same retention time) which results in two or more molecules to co-elute. Sometimes two different molecules can also have a similar pattern of ionized fragments in a mass spectrometer (mass spectrum). Combining the two processes makes it extremely unlikely that two different molecules will behave in the same way in both a gas chromatograph and a mass spectrometer. Therefore when an identifying mass spectrum appears at a characteristic retention time in a GC-MS analysis, it typically lends to increased certainty that the analyte of interest is in the sample.
Split/Splitless GC-MS inlets
Samples are introduced to the column via an inlet. This inlet is typically injection through a septum. Once in the inlet, the heated chamber acts to volatilise (vapourise) the sample. In a split system, a constant flow of carrier gas moves through the inlet. A portion of the carrier gas flow acts to transport the sample into the column. Another portion of the carrier gas flow gets directed to purge the inlet of any sample following injection (septum purge). Yet another portion of the flow is directed through the split vent in a set ratio known as the split ratio. In a splitless system, the advantage is that a larger amount of sample is introduced to the column. However, a split system is preferred when the detector is sensitive to trace amounts of analyte and there's concern about overloading the column.
Purge and Trap GC-MS
For the analysis of
volatile compounds a
Purge and Trap (P&T) concentrator system may be used to introduce samples. The target analytes are extracted and mixed with water and introduced into an airtight chamber. An inert gas such as
Nitrogen (N
2) is bubbled through the water; this is known as purging. The volatile compounds move into the headspace above the water and are drawn along a
pressure gradient (caused by the introduction of the purge gas) out of the chamber. The volatile compounds are drawn along a heated line onto a 'trap'. the trap is a column of
adsorbent material at ambient temperature that holds the compounds by returning them to the liquid phase. The trap is then heated and the sample compounds are introduced to the GC-MS column via a volatiles interface, which is a split inlet system. P&T GC-MS is particularly suited to volatile organic compounds (VOCs) and
BTEX compounds (aromatic compounds associated with petroleum).
Types of Mass Spectrometer Detectors
The most common type of mass spectrometer (MS) associated with a gas chromatograph (GC) is the quadrupole mass spectrometer, sometimes referred to as a Mass Selective Detector. Another relatively common detector is the ion trap mass spectrometer. Additionally one may find a magnetic sector mass spectrometer, however these particular instruments are expensive and bulky and not typically found in throughput laboratories. Other detectors may be encountered such as time of flight (TOF), tandem quadrupoles (MS/MS), or in the case of an ion trap MS
n where n indicates the number mass spectrometry stages.
Analysis
A mass spectrometer is typically utilized in one of two ways: Full Scan or Selective Ion Monitoring (SIM). The typical GC/MS instrument is capable of performing both functions either individually or concomitantly, depending on the setup of the particular instrument.
Full Scan MS
When collecting data in the full scan mode, a target range of mass fragments is determined and inputed into the instrument's method. An example of a typical broad range of mass fragments to monitor would be m/z 50 to m/z 400. The determination of what range to use is largely dictated by what one anticipates in being in the sample while being cognizant of the solvent and other possible interferences. A MS shouldn't be set to look for mass fragments too low or else one may detect air (found as m/z 28 due to nitrogen), carbon dioxide (m/z 44) or other possible interferences. Additionally if one is to use a very large scan range then sensitivity of the instrument is decreased due to performing fewer scans per second since each scan will have to detect a wide range of mass fragments.
Full Scan is useful in determining unknown compounds in a sample. It provides more information than SIM when it comes to confirming or resolving compounds in a sample. During instrument method development it may be common to first analyze test solutions in full scan mode to determine the retention time and the mass fragment fingerprint before moving to a SIM instrument method.
.....
Selective Ion Monitoring
In Selective Ion Monitoring (SIM) certain ion fragments are entered into the instrument method and only those mass fragments are detected by the mass spectrometer. The advantages of SIM are that the detection limit is lower since the instrument is only looking at a small number of fragments (for example three fragments) during each scan. More scans can take place each second. Since only a few mass fragments of interest are being monitored,
matrix interferences are typically lower. To additionally confirm the likelihood of a potentially positive result, it's relatively important to be sure that the ion ratios of the various mass fragments are comparable to a known reference standard.
Types of Ionization
After the molecules travel the length of the column, pass through the transfer line and enter into the mass spectrometer they're ionized by various methods with typically only one method being used as any given time. Once the sample is fragmented it'll then be detected, usually by an electron multiplier diode, which essentially turns the ionized mass fragment into an electrical signal that's then detected.
The ionization technique chosen is independent of using Full Scan or SIM.
Electron Ionization
By far the most common and perhaps standard form of ionization is
electron ionization (EI). The molecules enter into the MS (the source is a quadrupole or the ion trap itself in an ion trap MS) where they're bombarded with free electrons emitted from a filament, not much unlike the filament one would find in a standard light bulb. The electrons bombard the molecules causing a hard ionization that fragments the molecule, and the way in which a molecule fragment is usually typical for all EI techniques.
Chemical Ionization
In
chemical ionization a reagent gas, typically
methane or
ammonia is introduced into the mass spectrometer. Depending on the technique (positive CI or negative CI) chosen, this reagent gas will interact with the electrons and analyte and cause a 'soft' ionization of the molecule of interest. A softer ionization fragments the molecule to a lower degree than the hard ionization of EI. One of the main benefits of using chemical ionization is that a mass fragment closely corresponding to the molecular weight of the analyte of interest is produced.
Positive Chemical Ionization
In Positive Chemical Ionization (PCI) the reagent gas interacts with the target molecule, most often with a proton exchange. This produces the species in relatively high amounts.
Negative Chemical Ionization
In Negative Chemical Ionization (NCI) the reagent gas decreases the impact of the free electrons on the target analyte. This decreased energy typically leaves the fragment in great supply.
The primary goal of instrument analysis is to quantify an amount of substance. This is done by comparing the relative concentrations among the atomic masses in the generated spectrum. Two kinds of analysis are possible, comparative and original. Comparative analysis essentially compares the given spectrum to a spectrum library to see if its characteristics are present for some sample in the library. This is best performed by a computer because there are a myriad of visual distortions that can take place due to variations in scale. Computers can also simultaneously correlate more data (such as the retention times identified by GC), to more accurately relate certain data.
Another method of analysis measures the peaks in relation to one another. In this method, the tallest peak is assigned 100% of the value, and the other peaks being assigned proportionate values. All values above 3% are assigned. The total mass of the unknown compound is normally indicated by the parent peak. The value of this parent peak can be used to fit with a chemical formula containing the various elements which are believed to be in the compound. The isotope pattern in the spectrum, which is unique for elements that have many isotopes, can also be used to identify the various elements present. Once a chemical formula has been matched to the spectrum, the molecular structure and bonding can be identified, and must be consistent with the characteristics recorded by GC/MS. Typically, this identification done automatically by programs which come with the instrument, given a list of the elements which could be present in the sample.
A “full spectrum” analysis considers all the “peaks” within a spectrum. Conversely, selective ion monitoring (SIM) only monitors selected peaks associated with a specific substance. This is done on the assumption that at a given retention time, a set of ions is characteristic of a certain compound. This is a fast and efficient analysis, especially if the analyst has previous information about a sample or is only looking for a few specific substances. When the amount of information collected about the ions in a given gas chromatographic peak decreases, the sensitivity of the analysis increases. So, SIM analysis allows for a smaller quantity of a compound to be detected and measured, but the degree of certainty about the identity of that compound is reduced.
Applications
Environmental Monitoring and Cleanup
GC-MS is becoming the tool of choice for tracking
organic pollutants in the environment. The cost of GC-MS equipment has fallen significantly, and the reliability has increased at the same time, which has contributed to its increased adoption in environmental studies as cost is always a major consideration in this kind of work. There are some compounds for which GC-MS isn't sufficiently sensitive, including certain pesticides and herbicides, but for most organic analysis of environmental samples, including many major classes of pesticides, it's very sensitive and effective.
lcmS
Criminal Forensics
GC-MS can analyze the particles from a human body in order to help link a criminal to a
crime. The analysis of
fire debris using GC-MS is well established, and there's even an established American Society for Testing Materials (ASTM) standard for fire debris analysis.
Law Enforcement
GC-MS is increasingly used for detection of illegal narcotic, and may eventually supplant drug-sniffing dogs.
[1] It is also commonly used in forensic toxicology to find drugs and/or poisons in biological specimens of suspects, victims, or the deceased.
Security
A post-
September 11 development,
explosive detection systems have become a part of all
US airports. These systems run on a host of technologies, many of them based on GC-MS. There are only three manufacturers certified by the
FAA to provide these systems, one of which is Thermo Detection (formerly Thermedics), which produces the
EGIS, a GC-MS-based line of explosives detectors. The other two manufacturers are Barringer Technologies, now owned by Smith's Detection Systems and Ion Track Instruments, part of General Electric Infrastructure Security Systems.
Food, Beverage and Perfume Analysis
Foods and
beverages contain numerous
aroma compounds, some naturally present in the raw materials and some forming during processing. GC-MS is extensively used for the analysis of these compounds which include
esters,
fatty acids,
alcohols,
aldehydes,
terpenes etc. It is also used to detect and measure contaminants from spoilage or
adulteration which may be harmful and which is often controlled by governmental agencies, for example
pesticides.
Astrochemistry
Several GC-MS have left earth. Two were brought to
Mars by the
Viking program.
Venera 11 and 12 and
Pioneer Venus analysed the atmosphere of
Venus with GC-MS. The
Huygens probe of the
Cassini-Huygens mission landed one GC-MS on
Saturn's largest moon,
Titan. The material in the
comet 67P/Churyumov-Gerasimenko will be analysed by the
Rosetta mission with a chiral GC-MS in 2014.
Medicine
In combination with
isotopic labeling of metabolic compounds, the GC-MS is used for determining
metabolic activity. Most applications are based on the use of
13C as the labeling and the measurement of
13C/
12C ratios with an
isotope ratio mass spectrometer (
IRMS); an MS with a detector designed to measure a few select ions and return values as ratios.
Further Information
Get more info on 'Gas Chromatography-mass Spectrometry'.
|
External Link Exchanges
Do you know how hard it is to get a link from a large encyclopaedia? Well we're different and will prove it. To get a link from us just add the following HTML to your site on a relevant page:
<a href="http://gas_chromatography-mass_spectrometry.totallyexplained.com">Gas chromatography-mass spectrometry Totally Explained</a>
Then simply click through this link from your web page. Our crawlers will verify your link, extract the title of your web page and instantly add a link back to it. If you like you can remove the words Totally Explained and embed the link in article text.
As long as your link remains in place, we'll keep our link to you right here. Please play fair - our crawlers are watching. Your site must be closely related to this one's topic. Any kind of spamming, dubious practises or removing the link will result in your link from us being dropped and, potentially, your whole site being banned. |